> HOME
> ONLINE TESTS
> JOBS
*new
> DISCUSSION
(COMING SOON)
> CONTACT US
QC Coating Test 2:
Q. 1/30: Solvents and paints shall not be applied over substrate if temp. Greater than ….
800C
700C
500C
1000C
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 1/30
Test Progress : 3.33%
Q. 2/30: Lining is not suitable for
Corrosion
UV protection
Abrasion
All of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 2/30
Test Progress : 6.67%
Q. 3/30: FBE means
Fusion Bonded Epoxy
Enamel coating
Alkyde coating
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 3/30
Test Progress : 10.00%
Q. 4/30: Surface profile measurement instrument.
Dial micrometer
DFT gauge
Hypo dermic
Whirling hygro meter
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 4/30
Test Progress : 13.33%
Q. 5/30: VS% of Paint system is available in
SAES-H-001
SAES-H-002
SAES-H-101V
None of above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 5/30
Test Progress : 16.67%
Q. 6/30: Mis-coat thinning, after Primer application of In-organic Zinc
20 to 50 %
10 to 20 %
20 to 40 %
10 to 40 %
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 6/30
Test Progress : 20.00%
Q. 7/30: Holiday test shall not be done if temperature of substrate is more than…
780C
680C
88°C.
1000C
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 7/30
Test Progress : 23.33%
Q. 8/30: Surface cleaning requirement for Road crossing area pipeline coating except APCS-113C
Sa1
Sa2
Sa3
Sa2.5
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 8/30
Test Progress : 26.67%
Q. 9/30: Blasting pressure at Nozzle Side
100 PSI
40 PSI
90 PSI
50 PSI
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 9/30
Test Progress : 30.00%
Q. 10/30: Part of blasting equipment helped when a worker fainted down during abrasive blasting.
Blat pot
Knock out
Dead man’s Handle
Whip check
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 10/30
Test Progress : 33.33%
Q. 11/30: Hand tool cleaning will make the surface
Rough
Smooth and shiny
Very good Profile
A & C
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 11/30
Test Progress : 36.67%
Q. 12/30: Holiday test voltage in Tank, Vessel & other structure
67.5 Volts
2000 V
2400 V
none of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 12/30
Test Progress : 40.00%
Q. 13/30: Potassium Ferro cyanide test is used for detecting.
Dust on surface
Oil/Greece
Soluble Iron salts
None of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 13/30
Test Progress : 43.33%
Q. 14/30: Blisters formed on coating by
Water/solvent entrapment underneath the coating film.
Coating on sharp edges /corners will be
Removed / peeled off
A & C
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 14/30
Test Progress : 46.67%
Q. 15/30: Vial test is for
Air quality test
Salt contamination test
Test for cleanliness of abrasives
Test for cleanliness of surface
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 15/30
Test Progress : 50.00%
Q. 16/30: Stripe coating for Inorganic zinc coating shall be done at.
Before first coat application
After first coat application
A or B
None of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 16/30
Test Progress : 53.33%
Q. 17/30: Sealer coat application is possible immediately following thermal spray coating.
TRUE
FALSE
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 17/30
Test Progress : 56.67%
Q. 18/30: What Aramco Standard covered the Approved protective coating of Industrial Plants and Equipment.
SAES-H-101V
SAES-H-001
SAES-H-002
SAES-H-200
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 18/30
Test Progress : 60.00%
Q. 19/30: Max allowed chloride content for abrasives.
00 ppm
50 ppm
40ppm
100ppm
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 19/30
Test Progress : 63.33%
Q. 20/30: Method of coating application used for immersed service
Air spray coating
Airless spray coating
Thermal spray
Electrostatic coating
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 20/30
Test Progress : 66.67%
Q. 21/30: Required for Blotter testing
100 PSI
40 PSI
90 PSI
50 PSI
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 21/30
Test Progress : 70.00%
Q. 22/30: Attachment form submitted for coating inspector to review daily activities according to SAES-H-100-01
Attachment A and B
Attachment C
Attachment D
SSPC SP1
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 22/30
Test Progress : 73.33%
Q. 23/30: Amine is
Anti settling agent
Thinner
Curing
None of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 23/30
Test Progress : 76.67%
Q. 24/30: What are the two (2) components of paint
Binder & Vehicle
Pigment & additives
Pigment & Solvent
None of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 24/30
Test Progress : 80.00%
Q. 25/30: PE coating on piping can be done by Cross extrusion / sideways extrusion.
TRUE
FALSE
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 25/30
Test Progress : 83.33%
Q. 26/30: Hand tool cleaning
Solvent cleaning
Power tool cleaning
Flame cleaning
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 26/30
Test Progress : 86.67%
Q. 27/30: What Aramco standard you can find volume Solid
SAES-H-101V
SAES-H-001
SAES-H-002
SAES-H-200
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 27/30
Test Progress : 90.00%
Q. 28/30: What are the tools to test for abrasive blast cleaning
Surface comparator
Dial guage
Testex Tape (Press-o-film)
All of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 28/30
Test Progress : 93.33%
Q. 29/30: Sa 2.5 is
Therough Blast Clean
Very therough Blast Clean
White metal clean
none of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 29/30
Test Progress : 96.67%
Q. 30/30: What is SSPC standard for Power Tool Cleaning to Bare Metal?
SSPC-SP12
SSPC-SP11
SSPC-SP3
SSPC-SP2
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 30/30
Test Progress : 100.00%
Q. 31/30: Coating shall be done within ----hrs of blasting completion.
2
3
4
8
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 31/30
Test Progress : 103.33%
.
Select another Test
Return to categories