> HOME
> ONLINE TESTS
> JOBS
*new
> DISCUSSION
(COMING SOON)
> CONTACT US
QC Coating Test 1:
Q. 1/30: Dew point is temperature at which
Water freezes
Humidity decreases
The air is saturated
Condensation occurs
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 1/30
Test Progress : 3.33%
Q. 2/30: Requirement of Light used for confined space
24 V explosion proof
12V explosion proof
110V explosion proof
12V normal
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 2/30
Test Progress : 6.67%
Q. 3/30: Maximum temparature in Holiday Test on the bottom of the tank
80
120
50
230
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 3/30
Test Progress : 10.00%
Q. 4/30: For cone shaped tanks coating, Coating shall be done.
Shell side,
Roof to bottom.
Bottom
All of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 4/30
Test Progress : 13.33%
Q. 5/30: Gauge used for dry film thickness on thin film coating.
Digital gauge
Banana gauge
Pocket spot Instrument gauge
All of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 5/30
Test Progress : 16.67%
Q. 6/30: Howmany litter of paint(Area=100m², Avg DFT=300um)
30 L
60 L
300 L
150L
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 6/30
Test Progress : 20.00%
Q. 7/30: Min. Pressure at nozzle required for Abrasive blast cleaning.
90 PSI
40 PSI
120PSI
80PSI
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 7/30
Test Progress : 23.33%
Q. 8/30: Profile measurement range for X-Coarse testex tape.
20-50 Microns
38-50 Microns
40-65 Microns
38-115 Microns
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 8/30
Test Progress : 26.67%
Q. 9/30: Overspray is
Waste
Paint not hitting the target
A&B
None of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 9/30
Test Progress : 30.00%
Q. 10/30: PH value shows
Acid / alkaline nature
Phosphate value
Chloride value
None of above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 10/30
Test Progress : 33.33%
Q. 11/30: MSDS shall be used by.
Coating
Solvent
Cleaners
All of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 11/30
Test Progress : 36.67%
Q. 12/30: Blistering is caused by
Hygroscopic salt contamination
Dust contamination
over thickness
over thinning
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 12/30
Test Progress : 40.00%
Q. 13/30: FBE coating powder in liquid form stage is mentioned as
Flow stage
Gel stage
Powder
Curing
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 13/30
Test Progress : 43.33%
Q. 14/30: For internal FBE coating, the weld cap or internal protrusion shall not be more than
1.5 mm
2 mm
2.5 mm
5 mm
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 14/30
Test Progress : 46.67%
Q. 15/30: Thermometer is used to measure
Surface temperature
Relative Humidity
Dew point
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 15/30
Test Progress : 50.00%
Q. 16/30: This is the length of time after mixing which the paint should stand before use
Induction time
Pot life
shelf life
None of above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 16/30
Test Progress : 53.33%
Q. 17/30: Sigma paint can be over coated with Jotun
TRUE
FALSE
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 17/30
Test Progress : 56.67%
Q. 18/30: What is the WFT, If DFT=75µm, VS=50%
750µm
500µm
150µm
75µm
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 18/30
Test Progress : 60.00%
Q. 19/30: Max allowed speed of probe in Holiday test.
30 mm/s
3 mm/s
300mm/s
30 mm/m
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 19/30
Test Progress : 63.33%
Q. 20/30: Silica sand can use for abrasive blasting
TRUE
FALSE
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 20/30
Test Progress : 66.67%
Q. 21/30: Tip size 421 means
Angle 4°, Size 0.21"
Angle 40°, Size 0.021"
Angle 4°, Size 0.021"
Angle 40°, Size 0.21"
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 21/30
Test Progress : 70.00%
Q. 22/30: Min moisture content required for New concrete structure prior to coating.
0.14
0.1
0.04
0.004
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 22/30
Test Progress : 73.33%
Q. 23/30: Silica gel is not a good desiccant.
TRUE
FALSE
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 23/30
Test Progress : 76.67%
Q. 24/30: What is the required lighting in confind space?
110V ordinary lamp
12V ordinary lamp
12V explosion proof
24V explosion proof
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 24/30
Test Progress : 80.00%
Q. 25/30: Type of field adhesion test used for FBE coating.
Cross cut adhesion test
Dolly test
X cut adhesion test
All of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 25/30
Test Progress : 83.33%
Q. 26/30: Immersion coating consist of
Base, Curing - 2 CAN
Base, Curing, Thinner - 3 CAN
Base only
None of the above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 26/30
Test Progress : 86.67%
Q. 27/30: SSPC-SP7
Commercial blast cleaning
Brush off blast cleaning
Near white metal cleaning
White metal cleaning
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 27/30
Test Progress : 90.00%
Q. 28/30: Who will recommend the solvent type for coating
Coating Inspector
Manufacturer datasheet
Contractor
none of above
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 28/30
Test Progress : 93.33%
Q. 29/30: MEK Test
50 rub test
30 rub test
20 rub test
15 rub test
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 29/30
Test Progress : 96.67%
Q. 30/30: Solvents and paints shall not be applied over substrate if temp. Greater than ….
800C
700C
500C
1000C
Please select an option and click submit.
.
Your answer is correct. Welldone! Click next.
Sorry, your answer is incorrect. Click next.
Submit
Previous
Next
Q 30/30
Test Progress : 100.00%
.
Select another Test
Return to categories